May, 2009

The following tables show the factory settings for network addressing, user IDs, rack numbering, BladeCenter® unit and node numbering, I/O bay location numbering, and hostnames of the various IBM® System Cluster 1350™ components.


Table 1: Network addressing and hostnames





IP Address

Hostname

Component

172.20.0.1

mgt.cluster.com

Management node eth0 (cluster vlan)

172.30.0.1

mgt1.cluster.com

Management node eth1 (management vlan)

172.29.0.1

bmc

Management node alias eth0:1 (cluster vlan )

172.29.101.1*

bmc001

Node BMCs

172.20.1.1

storage001

Storage nodes

172.30.2.1*

triton01A

DS3000/DS4000 storage controllers (A, B)

172.20.101.1

node001

Compute nodes

172.40.101.1

hca001

HCA cards ib0 (cluster vlan)

172.20.4.1

user001

User nodes

172.30.10.1*

myri001

cis001


volt001

ql001


Myrinet or InfiniBand:

Voltaire 2004, 2012, 2036, 9096, 9288,4036, 4700,

QLogic 9024, 9080, 9120, 9240, 12200, 12300, 12800


172.30.20.1*

ts001

Terminal servers: Cyclades ACS32/ACS48

172.30.30.1*

rsa001, avocent001

RSA or Avocent MP5300

172.30.40.1*

cisco2960-001

10/100 Cisco switches

172.30.50.1*

bnt8000-001

bnt8100-001

brocb50c-001

brocb24x-001

brocfcx648

cisco3750-001

cisco4948-001

force50-001

mlnxis5030-001
smc8024-001

smc8848-001

smc8708-001

volt8500-001



1U/2U 1G and 10G Ethernet Switches

Blade Network Technologies 8000, 8100, 8126

Brocade Networks Netiron ZB50C(CES2048CX),
FCX648 (B48Y)

Cisco 3750, 3560, 4900M, 4948


Force10 S50, S2410

Mellanox IS5030


SMC 8848M, 8708, 8024

Voltaire 8500



172.30.60.1*

apc001

APC

172.30.70.1*

rcm001

RCM

172.30.80.1*

brocb08r-001

brocb16r-001

cisco6509-001

force150-001

force300-001

force600-001

force1200-001

force600i-001

force1200i-001

mlnxis5200-001

mlnxis5600-001





Enterprise Ethernet Switches

Brocade B08R (BigIron RX-8-AC), B16R (BigIron RX-16-AC)

Cisco 6509

Force10 E 600/E600i/E1200/E1200i and C150/C300

Mellanox IS5200 and

IS6500


172.30.85.1*

fc001

Fibre Channel switches

172.30.101.131*

mm001

BladeCenter management module

* Indicates the hard-coded IP address of the various Cluster 1350 components.


Table 2: Compute node IP addressing





Rack name

Network

Rack number

Node*

Rack1

172.20

101

1 to 84

Rack2

172.20

102

1 to 84

Example: rack 1, node 1 = 172.20.101.1

* Node numbering increases from the bottom of the rack upward.

* BladeCenter unit node numbering increases from the bottom of the rack upward and from left to right.


Table 3: BMC IP addressing





Rack name

Network

Rack number

Node

Rack1

172.29

101

1 to 84

Rack2

172.29

102

1 to 84

Example: rack 1, node 1 = 172.29.101.1




Table 4: BladeCenter IP Addressing BC-H 8852-xxx or 8677-xxx with an advanced management module (AMM)





Network

Rack number

I/O bay location number (1-10) + BladeCenter unit number (1-6)

172.30*

101

1 to 10 (SM I/O bay 1 - SM I/O bay 10) + 1 to 6 BladeCenter unit number

172.30*

102

1 to 10 (SM I/O bay 1 - SM I/O bay 10) + 1 to 6 BladeCenter unit number

172.30*

101

Advanced management module* 130 + 1 to 6 BladeCenter unit number
*Advanced management modules in the same BladeCenter unit share one IP address.

Examples: 172.30.101.34 - the switch module fitted to I/O bay 3 in BladeCenter unit 4 of rack 1

172.30.102.46 - the switch module fitted to I/O bay 4 in BladeCenter unit 6 of rack 2

172.30.106.104 - the switch module fitted to I/O bay 10 in BladeCenter unit 4 of rack 6

172.30.106.133 - the AMM for BladeCenter unit 3 of rack 6


Table 5: InfiniBand HCA IP Addressing





Network

Rack number

Rack name

HCA*

172.40

101

Rack1

1 to 84

172.40

102

Rack2

1 to 84

Example: rack 1, hca 1 = 172.40.101.1


*Host channel adapter (HCA) numbering increases from the bottom of the rack upward.

Table 6: Factory set user IDs and passwords





Hardware

User ID

Password

Comments

Avocent MP 5300

root

avocent

Default

APC switch

apc

apc

Default

ITouch terminal

access

system

Default

InReach terminal

InReach

access

Default

BNT switch

admin

admin

Default

Brocade

none

none

Default

Cyclades terminal

root

tslinux

Default

Cisco switch

(see Comments)

ibm1350

Press Enter for the userid prompt

SMC switch

admin

admin

Default

SMC 8024L2

admin

smcadmin

Default

AStT

(see Comments)

infiniti

Press Enter for the userid prompt

Fibre Channel switch

admin

password

Default

Force10

none

none

For priv exec, the password is force10

RSAs

USERID

PASSW0RD

The 0 in passw0rd is a zero

BladeCenter management module

USERID

PASSW0RD

The 0 in passw0rd is a zero

Cisco InfiniBand switch

admin

adminpass

Default

Mellanox

admin

admin

Default

QLogic InfiniBand switch

admin

adminpass

Default

Voltaire root:

br6000




Required for first log in (default)

Voltaire InfiniBand switch

admin

123456

Default

QLogic BC FC switch module

USERID

PASSW0RD

The 0 in passw0rd is a zero




Table 7: Operating system passwords


Operating system

USERID

Password

Management server

root

ibm1350

Nodes

admin

root


cluster

cluster

_________________________
IBM, BladeCenter and 1350 are trademarks of the IBM Corp. in the United States, other countries, or both. Other company, product, or service names may be trademarks or service names of others.
©Copyright International Business Machines Corporation 2007. All rights reserved.

US Government Users Restricted Rights – Use, duplication or disclosures restricted by GSA ADP Schedule Contract with IBM Corp.



IBM System Cluster 1350 factory settings




Verilənlər bazası müəlliflik hüququ ilə müdafiə olunur ©www.azrefs.org 2016
rəhbərliyinə müraciət

    Ana səhifə